In stations 11-17, workers complete the remaining tasks within the CRZ.
Station 11: Fully Encapsulating Suit with Hard Hat Removal
Fully encapsulated suit is removed with assistance of a helper and laid out on a dropcloth or hung up. Hard hat is removed. Hot weather rest station maybe set up within this area for personnel returning to site.
Station 12: SCBA Backpack Removal
While still wearing facepiece, remove backpack and place on table. Disconnect hose from regulator valve and proceed to next station.
Station 13: Inner Glove Wash
Wash with decon solution that will not harm the skin. Repeat as often as necessary.
Station 14: Inner Glove Rinse
Rinse with water. Repeat as many times as necessary.
Station 15: Face Piece Removal
Remove face piece. Deposit in container with plastic liner. Avoid touching face with fingers. Remove inner gloves and deposit in container with liner.
Station 16: Inner Glove Removal
Remove inner gloves and deposit in container with liner.
Station 17: Inner Clothing Removal
Remove clothing and place in lined container. Do not wear inner clothing off-site. There is a chance that it will still contain contaminants, which you could then transfer to other materials outside of the worksite.
Workers then cross the Contamination Control Line and enter the Support Zone for the final two stations.
To learn more about HAZWOPER visit our HAZWOPER 40 Hour Online Training web page.
THE BEST ONLINE TRAINING EXPERIENCE POSSIBLE
Fast
Your time is valuable. We've designed our site to be as fast as possible.
Easy to use
You'll never get lost or confused with us.
Immediate Access
There's no waiting period. Begin the course as soon as you sign up.
Anywhere Anytime
Internet connection and a computer, tablet, or smartphone.
Up to date
We update our courses as soon as new regulations come out.