The following procedures complete decontamination for workers wearing Level C PPE.

Station 11: Splash Suit Removal

With assistance of helper, remove splash suit. Deposit in container with plastic liner.

Station 12: Inner Glove Wash

Wash inner gloves with decon solution.

Station 13: Inner Glove Rinse

Rinse inner gloves with water.

Station 14: Face Piece Removal

Remove face piece. Deposit in container with plastic liner. Avoid touching face with fingers.

Station 15: Inner Glove Removal

Remove inner gloves and deposit in container with liner.

Station 16: Inner Clothing Removal

Remove inner clothing. Place in container with liner. Do not wear inner clothing off site since there is a possibility that small amounts of contaminants might have been transferred in removing the fully-encapsulating suit.