IATA Class 2 Packaging Specifications
The design, construction, and initial inspection and testing of cylinders must meet the ISO standards listed in Subsection 6.4.2.1. ISO standards are also provided that specify the construction materials and closures of the cylinders and closed cryogenic receptacles. The appropriate national authority must approve the conformity assessment system. This includes detailed requirements for the manufacturers and inspectors of the packaging. After inspection, each cylinder or receptacle must be certified that it meets the inspection and test requirements. The design type approval and certificate of compliance records must be maintained for at least 20 years.
Refillable cylinders and closed cryogenic receptacles must be marked with permanently affixed certification, operational, and manufacturing marks. The marks must be placed on the shoulder, top end, or neck of the cylinder or closed cryogenic receptacle or on a permanently affixed component.
The following certification marks must be applied:
- United Nations packing symbol
- Technical Standard used for design, construction, and testing
- State VRI code (see Appendix D.1 and D.2)
- Inspection body mark
- Date of initial inspection
The following operational marks must be applied:
- Test pressure in bar, preceded by the letters "PH" and followed by the letters "BAR"
- Mass of the empty cylinder, followed by the letters "KG"
- Minimum guaranteed wall thickness, followed by the letters "MM"
- For compressed gases, the working pressure in bar, preceded by the letters "PW"; for closed cryogenic receptacles, the maximum allowable working pressure, preceded by the letters "MAWP"
- For liquefied gases, the water capacity in liters, expressed to three figures, followed by the letter "L"
- For UN 1001, the total mass of the empty receptacle, the fittings and accessories, any coating, the porous mass, the solvent, and the saturated gas, followed by the letters "KG"
- For UN3374, the total mass of the empty receptacle, the fittings and accessories, any coating, and the porous mass, followed by the letters "KG"
The following manufacturing marks must be applied:
- Cylinder thread identification (not required for closed cryogenic receptacles)
- Manufacturer's mark
- Serial number
- For steel cylinders and composite cylinders with steel liners, the letter "H" showing compatibility of steel
Refillable cylinders must also be marked with the following inspection information:
- Identification of authorizing country (not required if the test and inspection is performed in the same country in which it was manufactured)
- Registered mark of the inspection body
- Date of the periodic inspection
Non-refillable cylinders and closed cryogenic receptacles must be marked with the same specifications as a refillable cylinder or receptacle, with the following exceptions:
- Non-refillable cylinders and closed cryogenic receptacles do not require the mass of the empty cylinder, the minimum wall thickness, or the identification of the cylinder thread.
- The words "DO NOT REFILL" must be included in the mark, and the letters must be at least 5 mm in height.
To learn more about IATA Dangerous Goods Regulations visit our IATA DGR Online Training Certification Courses web page.
THE BEST ONLINE TRAINING EXPERIENCE POSSIBLE
Fast
Your time is valuable. We've designed our site to be as fast as possible.
Easy to use
You'll never get lost or confused with us.
Immediate Access
There's no waiting period. Begin the course as soon as you sign up.
Anywhere Anytime
Internet connection and a computer, tablet, or smartphone.
Up to date
We update our courses as soon as new regulations come out.